languages:
Home About us Product Information Service Guest book Contact us
Msn | Yahoo | Skype | Gmail talk
  Categories
 Medical equipment
Oxygen Concentrator
Anesthesia Machine
Ventilator
Patient Monitor
Medical Air compressor
Anesthesia spare part
ECG Machine
B-ultrasound
Respiratory Humidifier
Eye Equipment
Anesthesia ventilator
Cpap machine
Home care product
Infant incubator
Defibrillator&AED
Infusion Pump
Syringe pump
X ray machine
Electrosurgical Unit
Non-contact Thermomer
Urine Analyzer
Specific Protein analyzer
Chemistry Analyzer
Hematology analyzer
Electrolyte analyzer
Coagulation Analyzer
Autoclaves & Sterilizers
Dental instrument
laryngoscope
Weight scale
Hemodialysis
centrifugal machine
laryngoscope
Blood pressure monitor
Fingertip Pulse Oximeter
Electronic blood pressure monitor
Fetal heart rate monitor
Piezo grid type atomizer
Moxibustion series
Tester
Hanging tower
Endoscope
 Medical furniture
Operation lamp
wheelchair
Ambulabce Stretcher
Stretcher
Manual Hospital Bed
Emergency Bed
Wheelchair cart
Operation Table
 Medical Consumables
Surgical gown
Breathing Bag
Manual Resuscitator

New Product
Featured Product
All Product
  More resources
· Color Doppler ultras
· The failure rate and
· Bipap respirator mas
· Portable X-ray machi
· ultrasonic probe how
· Fault analysis of ul
· Effect of ECG signal
· Operation Lamp repai
· Daily check of opera
  Contact Us

 


 


 


 

 
    Medical equipment > Ventilator
Product Name: ICU Ventilator WME700A
Model: WME700A
Application: ICU Room
Inquiry:

Technology Specification
Ventilator Mode:IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH,IMV, VCV, PCV

Display:High-definition 10.4” TFT colored LCD
Tidal Volume:20-2000 ml
Rate:1~99bpm
SIMV rate:2~20bpm 
I:E:4:1~1:8 
Trigger sensitivity:-1.0~2.0kPa
PEEP:0~25cmH2O
Pressure control:3~60cmH2O
SIGH: 1.5 times the inspiratory time (60 ~ 120 times adjustable)
Inspiratory platform:0~50%
Oxygen concentration :21%~100%
Pressure limit:5~60cmH2O 
Parameters for ventilation monitoring 
tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E,peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop) 
Safety alarm system 
Airway pressure alarm  
upper limit setting range   0.3~6.0 kPa 
lower limit setting range    0.2~5.0 kPa
Per-minute ventilation volume alarm  
upper limit setting range 3.0~30L/min  
lower limit setting range  1.0~10L/min 
VT alarm  
upper limit setting range 10~2000ml    
lower limit setting range  0~1800 ml 
Sustained high-pressure alarm 
it will give alarm when stress have consistently been higher than 2.5 kPa  
Suffocation alarm 
it will give sound and light alarm if there is no tidal volume input for 15 seconds    
Power  
AC 220V±10%     50Hz±1Hz  UPS, Storage battery 

Optional Configuration

Trolley,Air compressor