languages:
Home About us Product Information Service Guest book Contact us
Msn | Yahoo | Skype | Gmail talk
  Categories
 Medical equipment
Oxygen Concentrator
Anesthesia Machine
Ventilator
Patient Monitor
Medical Air compressor
Anesthesia spare part
ECG Machine
B-ultrasound
Respiratory Humidifier
Eye Equipment
Anesthesia ventilator
Cpap machine
Home care product
Infant incubator
Defibrillator&AED
Infusion Pump
Syringe pump
X ray machine
Electrosurgical Unit
Non-contact Thermomer
Urine Analyzer
Specific Protein analyzer
Chemistry Analyzer
Hematology analyzer
Electrolyte analyzer
Coagulation Analyzer
Autoclaves & Sterilizers
Dental instrument
laryngoscope
Weight scale
Hemodialysis
centrifugal machine
laryngoscope
Blood pressure monitor
Fingertip Pulse Oximeter
Electronic blood pressure monitor
Fetal heart rate monitor
Piezo grid type atomizer
Moxibustion series
Tester
Hanging tower
Endoscope
 Medical furniture
Operation lamp
wheelchair
Ambulabce Stretcher
Stretcher
Manual Hospital Bed
Emergency Bed
Wheelchair cart
Operation Table
 Medical Consumables
Surgical gown
Breathing Bag
Manual Resuscitator

New Product
Featured Product
All Product
  More resources
· Color Doppler ultras
· The failure rate and
· Bipap respirator mas
· Portable X-ray machi
· ultrasonic probe how
· Fault analysis of ul
· Effect of ECG signal
· Operation Lamp repai
· Daily check of opera
  Contact Us

 


 


 


 

 
    Medical equipment > X ray machine
Product Name: 50ma Mobile X Ray Machine WME910A
Model: WME910A
Application: Used for X-ray radiography in wards, especially in orthopaedic wards.
Inquiry:
Name 50ma Medical mobile x ray machine
Usage & Features
1. Used for X-ray radiography in wards, especially in orthopaedic wards. 2. Single focus point, high voltage silicon stack full-wave rectification. 3. kV, mA and s capacity interlocking control system, overload indicating system. 4. Wired manual exposure & remote control exposure 5. Sound and light indication during the course of exposure. 
Main Technical Specifications
Power Supply Voltage Single Phase AC 180~240V
Frequency 50 Hz
Current (Max., instantaneous) <20A
Power capacity greater than 5.5kvA
Internal resistance of power supply wire ≤1Ω
Maximum rated capacity Current(mA) Voltage (kvp) Exposure time(s)
30 90 0.08~6.3
40 90 0.08~4.0
50 90 0.08~1.0
80 0.08~2.5
 Timer 0.08s to 6.3s, in 20 shifts, electronic type
 Max distance from tube focus to the ground ≥1820 mm
 Min distance from tube focus to the ground ≤550 mm
 Remote control exposure distance ≥ 6m
 Max. exposure field 350×350 mm (when distance between X-ray tube focus and film is 650 mm)
 Max. exposure field 450×450 mm / when distance 1000mm
 Specification of x ray tube XD1-3/100, stationary anode, focus 2.3 x 2.3